Zhone IMACS-200 ユーザーズマニュアル

ページ / 294
E&M Ports
7-3
Figure 7-2 illustrates a Type II E&M signaling interface where the connecting equipment 
(normally a PBX or other inter-office carrier systems) originates on the M-lead. The 
connecting equipment provides a contact closure between the M and SB leads at the interface 
to send an 0ff-hook (originate) and an open between the M and SB leads at the interface to 
send an on-hook. The IMACS-200 provides a contact closure between the E and SG leads at 
the interface to send on off-hook to the connecting equipment and an open between the E and 
SG leads to send an on-hook
Figure 7-2.Type II E&M Signaling