Zhone IMACS-200 ユーザーズマニュアル

ページ / 294
E&M Ports
7-7
Table 7-1. Main Screen Actions
Table 7-2, “Main Screen Option Settings and Defaults,” on page 7-7 summarizes the 
configuration settings for the E&M port, along with the available and factory-default option 
settings. The parameters and settings are also described in the following paragraphs.
Table 7-2.  Main Screen Option Settings and Defaults
Notes:
1. The extended setting range for the IMACS-200 E&M port is from -16.3 to +7.5 dB.
2. When a WAN or SRV port has not been selected, or when the mode it to, the default 
for Signal Conversion is n/a. When the mode has been selected to be e&m, then the 
default is off.
Action
Function
Save
Saves changes to settings.
Undo
Returns all settings to the last saved state.
Refresh
Updates certain time-related information fields that are not automatically 
updated (i.e., test status).
Copy
Copies the contents of the current column to the next column. Useful if you 
change a lot of entries in one column and wants to repeat those changes in 
subsequent columns.
Test
Access is given to the test screen
taBs
Index into the signaling conversion screen.
Main
Returns to the System Main Screen. If you make changes to settings and do 
not save them, you will be prompted to save or lose changes.
Parameter
User Options
Notes
Default
STATE
stdby     actv
stdby
WAN/SRV
none     wan-1    wan-2    wan-3    wan-4    owan-1   owan-2   
owan-3   owan-4
none
TS
01-24 or 01-31
01
MODE
to e&m I e&m II e&m IV e&m V
to
Rx TLP
-16.3 dB to +7.5 dB
0
Tx TLP
-16.3 dB to +7.5 dB
1
0
CODING
u-law     a-inv
u-law
LB
off     dgtl     anlg
off
PATTRN
none     D-mW 
none
SIG CONV
n/a off on
23
off