Zhone IMACS-200 ユーザーズマニュアル

ページ / 294
Sub Rate Data Ports
8-9
SRU Ports
Test Screen
Table 8-4. Test Screen Actions
Table 8-5. Test Screen Option Settings and Defaults
BERT
Bit Error Rate Tester (BERT) sends a data pattern and measures the bit error rate (BER) on the 
selected SRU port. The patterns that can be selected are offmark (all ones), space (all zeros), 
1:1 (alternating 10101010), 1:7 (10000000), 511 (511 test pattern), and 2047 (2047 test 
pattern).
DIR
The Direction (DIR) setting allows you to specify where the BERT test signal should be 
directed. The first option is net (network) which means that the test signal will be transmitted 
through the system toward the Wide Area Network (WAN). The user option means that the 
signal will be directed toward the attached DTE device over the RS-232 interface.
Action
Function
Save
Saves changes to settings.
Undo
Returns all settings to the last saved state.
Refresh
Updates certain time-related information fields that are not automatically 
updated (i.e., test status).
InsertErr
Allows you to manually insert a single error into the clear data signal.
Clear
Clears the Test Screen and resets all counters to zero.
Main
Returns to the SRU port Main Screen. If changes are made to settings and 
not saved, you will be prompted to save or lose changes.
Parameter
User Options
Default
BERT
off     mark     space     1:1     1:7     511     qrss     2047
off
DIR
net     user
net
CTS
norm     off     on
norm
RLSD
norm     off     on
norm
SYNC
information only–no user options
*****
BE
information only–no user options
*****
ES
information only–no user options
*****
SES
information only–no user options
*****
CSES
information only–no user options
*****
OSS
information only–no user options
*****
BER
information only–no user options
*****
ELAP
information only–no user options
*****
RTS
information only–no user options
*****
SR OSS
information only–no user options
*****
LB ST
information only–no user options
*****