Zhone IMACS-200 ユーザーズマニュアル

ページ / 294
8-10 
Sub Rate Data Ports
Model No.
Running Head
Test Screen
SRU Ports
CTS
The Clear To Send (CTS) option allows you to define whether the CTS control lead should be 
held on (high) or off (low). Selecting either on or off will override the selection made in the 
SRU port screen. The third option is norm (normal) which means that CTS will behave as 
described in Table 8-3.
RLSD
The Receive Level Signal Detect (RLSD) option allows you to define whether the RLSD 
control lead should be held on (high) or off (low). The third option is norm (normal) which 
means that RLSD will behave as described in Table 8-3.
SYNC
The Synchronization (SYNC) field tells you if the integrated BERT has achieved 
synchronization either with itself via a remote loopback or with the remote test equipment. 
Since this is an information-only field, there are no user-selectable parameters.
BE
The Bit Error field shows the total number of bit errors logged. Since this is an 
information-only field, there are no user-selectable parameters.
ES
The Errored Seconds field shows the total number of seconds in which any errors were 
detected. Since this is an information-only field, there are no user-selectable parameters.
SES
The Severely Errored Seconds (SES) field shows the total number of seconds in which the bit 
error rate exceeded one bit per thousand (1 x 10
-3
). Since this is an information-only field, there 
are no user-selectable parameters.
CSES
The Consecutive Severely Errored Seconds (CSES) field is triggered by the occurrence of ten 
consecutive Severely Errored Seconds. Once triggered, the CSES field will increment (by 
one) for each elapsed second until the system logs ten consecutive non-Severely Errored 
Seconds. Since this it an information-only field there are no user-selectable parameters.