Zhone IMACS-200 ユーザーズマニュアル

ページ / 294
9-12 
High Speed Data Ports
Model No.
Running Head
SES
The Severely Errored Seconds (SES) field indicates the total number of seconds in which the 
bit error rate exceeded one bit per thousand (1 x 10
-
3
). This is an information-only field; it is 
not user-configurable.
CSES
The Consecutive Severely Errored Seconds (CSES) field is triggered by the occurrence of ten 
consecutive Severely Errored Seconds. Once triggered, this field will increment (by one) for 
each elapsed second until the system logs ten consecutive non-Severely Errored Seconds. This 
is an information-only field; it is not user-configurable.
OSS
The Out of Synchronization Seconds (OSS) field indicates the number of seconds that the 
HSU BERT has been out of synchronization. This is an information-only field; it is not 
user-configurable.
BER
The Bit Error Rate (BER) field indicates the rate at which errors are being logged. The system 
calculates BER by dividing the number of bit errors (BE) by the total number of bits 
transmitted during the test. This is an information-only field; it is not user-configurable.
ELAP
The Elapsed time (ELAP) setting indicates the running tally of the total number of seconds 
during the test. This is an information-only field; it is not user-configurable.
LB ST
The Loopback State (LB ST) field indicates whether there are any remotely-initiated 
loopbacks currently active on the HSU port. This field displays latching loopbacks initiated 
from a remote device via in-band loop-up codes. In addition to none, the system will display 
V.54 or FT1 (fractional T1). This is an information-only field; it is not user-configurable.