OHSU Ports
10-3
Table 10-1. OHSU port Main Screen Actions
Table 10-2. OHSU port Setting Options and Defaults
STATE
The State setting determines whether the port is active or inactive. An inactive port does not 
occupy time slots on a WAN link. Set State to standby (stdby) for ports you are not using or 
have not yet configured. Set it to active (actv) for ports that are ready for use. 
WAN
The WAN setting identifies the WAN or OWAN port to which the output of this port is 
directed. The options are wan-1 to wan-4, and owan-1 to owan-4.
MODE
The Mode parameter appears for information only. The OHSU is fixed in the MUX mode.
Action
Function
Save
Saves changes to settings.
Undo
Returns all settings to the last saved state.
Refresh
Updates certain time-related information fields that are not automatically 
updated (i.e., performance and test data).
Main
Returns to the System Main Screen. If changes are made to settings and not 
saved, you will be prompted to save or lose changes.
Parameter
User Options
Default
STATE
stdby actv
stdby
WAN/SRV
none     wan-1    wan-2    wan-3    wan-4    
owan-1   owan-2   owan-3   owan-4
none
MODE
mux
mux
TS
table (up to 12 TS)
no assignment
RATE
64k 64k
TX CLOCK
int (mux MODE)
int
LOCAL LB
off user net
off