Zhone IMACS-200 ユーザーズマニュアル

ページ / 294
OWAN Ports
13-5
Figure 13-3.Typical OWAN port Main Screen
The bottom highlighted line on this screen lists several actions you can perform from the 
screen. To perform an operation, simply press the uppercase letter associated with the desired 
action. For example, to save your option settings, type “s”. Table 13-2 lists the actions you can 
perform.
13.4
OWAN Port Main Screen Actions
Table 13-2. OWAN Port Main Screen Actions
STATE
The state is the only user-editable field at this level. Options are to place the port standby 
(stby), active (actv) or redundant (rdnt).
Action
Function
Save
Saves changes to settings.
Undo
Returns all settings to the last saved state.
Refresh
Updates certain time-related information fields that are not automatically 
updated (i.e., performance and test data).
sWitch
Switches activity from one port to the other.
pOrts
Status and change screens for each WAN port contained in the E2 or DS2.
Main
Returns to the System Main Screen. If changes are made to settings and not 
saved, you will be prompted to save or lose changes.