Diagnostics
14-3
System Testing and Diagnostics
User port Diagnostics
14.3.2 Voice Diagnostics
The software-initiated diagnostics supported are voice ports include the setting of both analog 
and digital loopbacks toward the network and the generation of Quiet Tone and a Digital 
MilliWatt signal on a port-by-port basis. The operator can also monitor and set the state of the 
analog leads of any FXS or E&M port. They can set and monitor the state of the ABCD 
signaling bits of the digitized voice signal. In cross-connect system, test functionality also 
includes the ability to generate test tones (300Hz, 1 kHz and 3 kHz) and transmit those toward 
the user side or the network side of the system. The table below shows detailed information 
on the diagnostic capabilities of the Voice ports.
4-wire E&M 2-wire FXS
On-port loopbacks
Analog Toward Network
Yes
Yes
Digital Toward Network
Yes
Yes
Signaling Manipulation
Set Status of Analog Interface Leads
Yes
Yes
Set Transmit ABCD Signaling Bits
Yes
Yes
Set Receive ABCD Signaling Bits
Yes*
Yes*
Monitor Status of Analog Interface 
Leads
Yes
Yes
Monitor Status of Transmit ABCD 
Signaling Bits
Yes
Yes
Monitor Status of Receive ABCD 
Signaling Bits
Yes
Yes
Tone Generation
Tone Supported
300 Hz
Yes*
Yes*
1 kHz
Yes*
Yes*
3 kHz
Yes*
Yes*
Quiet Tone
Yes
Yes
Digital MilliWatt
Yes
Yes
Tone Direction
Toward User
Yes
Yes
Toward Network
Yes
Yes