Zhone IMACS-200 ユーザーズマニュアル

ページ / 294
A-2 
System Standards and Specifications
Model No.
Running Head
A.3
Chassis Standards
A.3.1
Dimensions
A.3.2
Chassis Power
A.3.3
Environment
A.3.3.1
Ambient Temperature and Humidity
Ambient temperature and humidity as per IEEE 1613 - 2003 Section 4.1.
Ambient refers to conditions at a location 30 cm (11.81 inches) from the surface of the unit 
enclosue while in operation.
A.3.3.2
Airflow
The IMACS-200 includes two fans. The fans are temperature controlled to automatically turn 
on and off as needed. 
Chassis Description
Model 
Number
Height
Width
Depth
Weight
in
cm
in
cm
in
cm
lb.
kg
Steel Chassis , Dual-Powered, 
OHSU.
IMACS-200
3.47
8.8
9.48
24.1
17.31
44.0
10.0
4.5
Chassis Description
Model 
Number
AC Power (50-60 Hz)
DC Power
Power 
Consumption
110 VAC
220 VAC
-48 VDC
125 VDC
Watts
Steel Chassis , Dual-Powered, 
OHSU.
IMACS-
200
115 VAC
104 to 135 
VAC
175 VAC 
to 264 
VAC
-40 VDC 
to -60 
VDC
125 (typical)
500 W 
(maximum)
Temperature 
C / 
F\
Humidity
Operate
Storage
Operate
-40
o
C to 70
o
C
-40
o
F to 158
o
F
-50
o
C to 85
o
C
-58
o
Fto 185
o
F
55 to 95% relative 
humidity, non 
condensing
Rate of temperature change
30 
o
 C/hr (54 
o
 F/hr)