System Operation
3-17
System Configuration and Operation
Alarms
Table 3-2. Alarm Filters
WARNING!Alarm Modifiers
Each alarm may also be designated as I=infom=minor, M=major or C=crit. The filter 
modifier appears on both the active alarm and alarm history screens.
Filter
Alarm
Meaning
NOS
No Signal
Incoming WAN signal is lost.
LOS
Loss of Synchronization
Frame Alignment is lost.
YEL
Yellow Alarm
The system has received a Yellow Alarm signal from a remote device. 
Usually received when the device loses WAN signal or synchronization.
AIS
Alarm Information Signal
The system has received a Blue Alarm signal from a remote device. Usually 
received when the remote or intermediate device has a major failure.
CGA_RED
Carrier Group Alarm - Red
The local incoming WAN signal has a serious problem and trunk 
conditioning is started. After receiving a RED alarm (NOS or LOS) for 2-3 
seconds, the system initiates the appropriate trunk conditioning sequence 
(see voice ports for information about the TC_CGA setting) and sends a 
Yellow Alarm to the remote device. If the system is in drop/insert mode, it 
also sends an AIS signal to the downstream equipment.
CGA_YEL
Carrier Group Alarm - Yellow
The system has initiated trunk conditioning in response to a Yellow Alarm 
from a remote device. After 2-3 seconds, the system initiates the appropriate 
trunk conditioning sequence (see voice ports for information about the 
TC_CGA setting).
ERR
Excessive Error Rate
The error rate measured by the system has exceeded the threshold set on the 
WAN port.
SENSOR
Alarm port Sensor
The Alarm port sensor has received an alarm indication from an attached 
device.
HI-TEMP
Temperature Alarm
The IMACS-200 has exceeded it’s ability to regulate the temperature in the 
unit, and external action is required.
FANFAIL
Cooling Fan Failure
One of the two supplied fans has failed.
UCA
User port/port alarm
One or more active ports on a user port are not working properly. Voice ports 
will show an alarm for excessive signaling transitions and data ports will 
show an alarm for exceeding the data error threshold.
RESET
System reset
The system has been reset by either loss of power or by a system software 
upgrade.
ACO
Alarm Cut-Off
The ACO option forces you to manually clear certain alarms. Without this 
option, self-correcting alarms might not be noticed. When the ACO option is 
set to either Report or Log and the modifier is set to Major, alarms will report 
normally but will also generate an ACO alarm. If the modifier is set to Minor, 
it will not generate the ACO alarm. If the filter is set to Ignore, no alarms will 
be generated. This can depend on whether or not the IMACS-200 is set for 
latch or cur.
SYNC
Clock Sync Alarm
The SYNC alarm is generated when either the primary or secondary external 
clock source is lost. This alarm is in addition to the condition that lost the 
clock source (CGA-RED or OOS).