System Operation
3-19
System Configuration and Operation
Cross-Connecting (XCON)
Figure 3-12.Typical Alarm History Screen
3.8
Cross-Connecting (XCON)
From the System Main Screen, you can access a Cross-Connect Screen by pressing “x” 
(Xcon) that lets you cross-connect WAN time slots between T1 links. For a detailed 
description of making connections on and through the IMACS-200, see Section 3.10 on page 
25 for
 information regarding making and managing cross-connects.
3.9
System Level Maintenance
You can also go from the System Main Screen to a Test and Debug Screen, by pressing “y” 
(sYstem) which allows you to perform system-level maintenance operations. You can back up 
the system configuration onto an external computer after saving and subsequently editing it, 
and (if necessary) you can restore that configuration to the system (refer to the backup and 
restore section later in this chapter
). You also can erase the system configuration and restart 
the system with a single “zip” command. 
3.9.1
Test, Debug, Backup & Restore
Advanced configuration and diagnostics are available through the use of the sYs (sYstem
command from the System Main Screen. Pressing “y” brings up the Test and Debug screen 
shown in Figure 3-13.