System Operation
Model No.
Running Head
System Level Maintenance
System Configuration and Operation
I P and netmask parameters must be set. You may need to change the routing table on your 
PC to include the IMACS-200 ethernet address as the gateway, or the local host address 
as the gateway for the system receiving the file as the destination IP address,
Figure 3-15.Setting the Host IP address
Note:
Your PC must have some sort of TFTP or TFTPD server software installed and 
running when you are downloading the binary files to the system. If you are using 
TFTPD type software it is easier if you set the root directory to indicate where the 
binary file is located at the TFTPD root screen. This eliminates the need to enter a 
path at the file name screen during the download process. If you are running a TFTP 
software package, consult the user guide accompanying the software for details on 
configuring and using the software.
3.9.5
TFTP Backup for 1.x.x
Follow the instructions listed below to perform a TFTP backup.
1. Log into the Integrated Access System using the Manager Password.
2. Press “Y” for System at the main menu.
3. At the Test and Debug screen press “B” for Backup.
4. The NV Ram Backup screen will appear. If the Protocol selected is xmodem, press Enter
You will be shown the option of tftp on the bottom of the screen. Use the right or left arrow 
key to move to tftp, and press Enter