3-34 
System Operation
Model No.
Running Head
Cross-Connecting WAN Time Slots
System Configuration and Operation
WARNING!
When cross-connecting multiple independent data DS0 time slots (sequentially grouped time 
slots should work) for data. Super-rate [data type cross-connect] is multiple DS0s sequentially 
assigned between WAN aggregates in a cross-connect system. DO NOT attempt to save time 
by cross-connecting independent data time slots as one super-rate circuit (could cause data 
errors.) This limitation does not apply to voice time slots.
Figure 3-25.New Circuit Selection and ID Assignment
W/U
The first WAN Unit (W/U) column is the T1 link in which the pass-through connection begins 
(since these circuits are bi-directional, the concept of beginning or ending is used for 
illustrative purposes only). The options are all WAN ports and ports, and the identification 
uses the same convention (wan-1, wan-2, etc.) seen earlier. If a WAN port is not present in 
the W/U selected, an error message is generated.