Zhone IMACS-200 ユーザーズマニュアル

ページ / 294
System Operation
3-39
System Configuration and Operation
Cross-Connect Actions
3.14
Cross-Connect Actions
Figure 3-5 summarizes the actions you can perform from the Cross-Connect Screen. These 
actions appear at the bottom highlighted line of the screen.
Table 3-5. Cross-Connect Screen Actions
Action
Function
Add
Allows you to program additional pass-through cross-connects in the system. If 
mistakes are made during the add process, pressing the up arrow or down arrow 
key will terminate this operation.
uPdate
Initiated by pressing the "p" key. With this command, users can change any of the 
parameters of a pass-through connection. Use the arrow keys to highlight the area 
to be changed and close the transaction using the "s" (Save) command.
dElete
Initiated by pressing the "e" key. Use this command to delete existing 
pass-through connections. The system will prompt users to delete the circuit, and 
the "y" key must be pressed to complete the transaction.
pgUp
Initiated by pressing the "u" key. Since the system can handle many different 
cross-connect circuits, users may exceed a single screen. New pages will be 
added automatically to accommodate additional circuits. The page count feature 
at the top of the screen shows the current page and the total amount of 
cross-connect pages. Use this command to scroll up through the pages of 
cross-connect information. 
pgDn
Initiated by pressing the "d" key. This action is similar to the pgUp command. 
Use this command to scroll down through the pages of cross-connect information. 
View all or 
View net
The View all action is initiated by pressing the "v" key. T
Main
Return to the Main IMACS-200 screen.