Page 
lOCATINg STOvE continued…
Fig. 5a – Front View
 Minimum Clearance Dimensions  
from Combustible Surfaces
Fig. 5b – Side View
 Minimum Clearance Dimensions  
from Combustible Surfaces
13"
13"
CORNER CLEARANCES
5.  Recheck  clearances  from  the  stove,  
connector  stove  pipe,  and  corner  clearances 
using  the  illustrations  in  figures  3–5  and  
your  local  building  codes  or  fire  protection  
ordinances.  
 
NOTE: Drywall faced with brick or stone must 
be considered a combustible surface.
Fig. 4 – Top View
 Minimum Corner Clearances  
from Combustible Surfaces
cautIon: Keep fuRnIshIngs and otheR  
coMbustIble MateRIals away foRM 
the  stove  and  outsIde  MInIMuM 
cleaRances.
6.  do  not  Install  thIs  stove  In 
a   M o b I l e   h o M e ,   M a n u fa c -
tuRed  hoMe,  tRaIleR  oR  tent 
–  no    eXceptIons!  (HUD  Federal  
Standard: 24 CFR Ch.xx)
7.  The  clearances  provided  are  minimum  
dimensions determined by OMNI-Test Labo-
ratories,  Inc.,  the  manufacturer’s  testing  
laboratory.  Installation  of    this  stove  must  
comply  with  the  latest  edition  of  NFPA  211 
for reduced clearances and/or your local build-
ing  code  rulings.  Use  whichever  minimum  
dimensions are LARGEST.
CAUTION:  FAILURE  TO  FOLLOw  THESE 
m I N I m U m   C L E A R A N C E   R E q U I R E -
mENTS  mAY  RESULT  IN  AN  UNSAFE   
INSTALLATION AND COULD CAUSE A FIRE.
8.  This  stove  meets  U.S.  Test  Standard: 
UL 1482-1996.
9.  Always locate stove to provide a source of fresh 
air into the room where the unit is installed.  
Failure to do so may result in air starvation of 
other fuel burning appliances and the possible 
development of hazardous conditions.