IMPORTANT:
MAKE THESE 
CONNECTIONS
DIRECTLY TO
SCREW TERMINALS
AS SHOWN.
T
O KEYP
AD RED WIRE
T
O KEYP
AD BLK WIRE
T
O KEYP
AD 
YEL
WIRE
T
O KEYP
AD GRN WIRE
T
O KEYP
AD BLK WIRE
T
O KEYP
AD RED WIRE
T
O KEYP
AD GRN WIRE
T
O KEYP
AD 
YEL
WIRE
Figure 6. Using A Supplementary Power Supply For Keypads
Preliminary Check-out Procedure
If you want to check that the system is working before connecting field wiring
from zones and devices, do the following:
1. Temporarily connect a 1000 ohm end-of-line resistor across each of the
basic hard-wire zones 1–6, as shown in the Summary of Connections
diagram.
Without actual zone wiring or EOL resistors connected, the keypads in the
system will not display the “Ready” message.
2. Power up the system temporarily by plugging the AC transformer
(previously wired to the control) into a 120VAC outlet.
3. Bus y
 
 
S ta ndby  (Alpha keypads) or 
dI
 (Fixed-word keypads) will be
displayed.
After approximately 1 minute *, the green “READY” LED (or “POWER”
LED on some types of keypads) should light, and the word 
READY
 (Fixed-
word keypads), or 
DISARMED...READY TO ARM 
(Alpha keypads) should
be displayed.
* To bypass the 1-minute delay, press  plus 0.
If the “Ready” message is not displayed on any of the keypads in the
system, or a “Not Ready” message is displayed, check the keypad wiring
connections, and make sure each of the 6 basic hard-wired zones has a
1000 ohm resistor connected across its terminals.
4. When you get the proper “Ready” displays on the keypad(s), the system is
functioning properly at this point.
Do not remove the EOL resistors until you are ready to make connections to
the hard-wired zones, to allow for testing later in the manual.
If an OC or OPEN CIRCUIT display is present on the keypad, data from the
control is not reaching the keypad. Check the wiring.