Viking Technology Technology Computer Drive slim sata ユーザーズマニュアル

ページ / 48
 
Manual 
6/12/2014 
PSFEM1XXXGPXXX 
Viking Technology 
Revision B4 
 
Page 20 of 48 
www.vikingtechnology.com 
 
 
more by erasures and writes over time. That is, it determines actual cell wear, not 
simply assumed wear normalized to write/erase events. The controller employs 
this information in its superior wear-leveling algorithm along with its ongoing 
record of writes and erasures, to ensure each block is impacted by P-E cycles no  
more than the average. The result is an SSD that is far more reliable across its 
full capacity and over a far greater length of time. The controller uses both static 
and dynamic wear-leveling algorithms to globally manage cell degradation to 
approximately 2% between least worn and most worn cells or to the value 
specified in the S.M.A.R.T Wear Range Delta command (ID=177, Opcode=0xB1)  
 
2.5.3.2   Write Operation Reduction 
The controller uses intelligent algorithms to minimize P-E cycles through 
aggregation, virtualization, and difference processing. It is uniquely effective in 
reducing the wear and maintaining the reliability of the overall pool of Flash 
memory blocks by intelligently minimizes re-writes of identical data, to maximize 
the effectiveness of the wear-leveling process.  
 
 
2.6  Data Security  
Element SSD supports AES-128 encryption and ATA Secure Erase features to 
protect sensitive data.