Viking Technology Technology Computer Drive slim sata ユーザーズマニュアル

ページ / 48
 
Manual 
6/12/2014 
PSFEM1XXXGPXXX 
Viking Technology 
Revision B4 
 
Page 34 of 48 
www.vikingtechnology.com 
 
 
Handling and reporting error conditions relating to the updating of S.M.A.R.T. 
logs and S.M.A.R.T. Attributes is accomplished the same as handling error 
conditions experienced while saving user data. Likewise, handling and reporting 
error conditions relating to other processes (including background processes) 
that occur while updating S.M.A.R.T. logs and S.M.A.R.T. Attributes is 
accomplished the same as handling such error conditions while saving user data. 
S.M.A.R.T. logs are validated by affecting the events being detected and logged; 
the S.M.A.R.T. log always reflects the event that occurred, whether that event is 
injected artificially or occurs independently. 
5.1.3  S.M.A.R.T. Attributes 
5.1.3.1 Supported (Baseline) Attributes 
The following table shows the supported S.M.A.R.T. attributes. 
Table 5-5: Baseline S.M.A.R.T. Attribute Summary  
ID 
Hex 
Attribute Name  
Description  
0x01 
Raw Read Error Rate  
Raw error rate related to ECC errors. 
Correctable and uncorrectable RAISE errors 
are included in the error event count. (UECC 
+ URAISE)  
0x05 
Retired Block Count  
Tracks the total number of retired blocks.  
0x09 
Power-On Hours (POH)  
Count of hours in power-on state. The raw 
value of this attribute shows total count of 
hours in power-on state.  
12 
0x0C 
Device Power Cycle Count  
This attribute indicates the count of full hard 
disk power on/off cycles.  
171 
0xAB 
Program Fail Count  
Counts the number of flash program failures  
172 
0xAC 
Erase Fail Count  
Counts the number of flash erase failures  
174 
0xAE 
Unexpected Power Loss 
Count 
Counts the number of unexpected power loss 
events since the drive was deployed. 
177 
0xB1 
Wear Range Delta 
Returns the percentage difference in wear 
between the most worn block and the least 
worn block. 
181 
0XB5 
Program Fail Count 
(Identical to Attribute 171) 
182 
0XB6 
Erase Fail Count 
(Identical to Attribute 172) 
187 
0xBB 
Reported Uncorrectable 
Errors  
This attribute tracks the number of 
uncorrectable RAISE (URAISE) errors 
reported back to the host for all data access 
commands.  
194 
0xC2 
Temperature  
Temperature assuming an on-board sensor 
connected via Industry Standard Two Wire 
Interface (ISTW) interface to the controller. 
195 
0xC3 
ECC On the Fly Count  
This attribute tracks the number of 
uncorrectable errors (UECC).  
196 
0xC4 
Reallocation Count  
This attribute tracks the # of blocks failing 
programming which are reallocated.