Viking Technology Technology Computer Drive slim sata ユーザーズマニュアル

ページ / 48
 
Manual 
6/12/2014 
PSFEM1XXXGPXXX 
Viking Technology 
Revision B4 
 
Page 45 of 48 
www.vikingtechnology.com 
 
 
 Attribute Sector 
The S.M.A.R.T. Attribute Sector defines attribute format and the data structure is 
defined in the following table. 
 
Table 5-7: S.M.A.R.T. Attribute Data Structure 
Byte 
Description 
0:1 
S.M.A.R.T. structure version number 
First Stored Attribute Number (i.e. “1” for RawErrorRate) 
3:4 
Status 
Nominal value 
Worst value since SSD was deployed 
7:12 
Raw Data 
13 
Reserved 
14:25 
Next Stored Attribute Number (ie “3” for “Retired Block Count”) 
26:361 
Next Stored Attribute Numbers (max 30 collected Attributes, including 
above) 
362 
Off-line data collection status 
363 
Self-test execution status byte 
364:365 
Total time to complete off-line data collection (in seconds) 
366 
Reserved 
367 
Off-line Data Collection capability 
368:369 
S.M.A.R.T. capability 
370 
Error Logging Capability (bit 0 set = device error logging supported) 
371 
Next Self Test Step 
372 
Short Self Test routine recommended polling time (in minutes) 
373 
Extended Self Test routine recommended polling time (in minutes) 
374 
Recommended polling time for Conveyance Self Test 
375:376 
Time for Extended Self Test if > 255 (ie, 373 to FFh) 
377:385 
Reserved 
386:510 
Vendor Information 
511 
Checksum of data structure (generated on retrieval of stored data) 
Notes: Bytes 2:361 are vendor unique 
 
 
5.1.4  Threshold Sector 
The S.M.A.R.T. Threshold Sector defines attribute trip thresholds. Attributes are 
compared to the thresholds when the S.M.A.R.T. Return Status Command (DA) 
retrieves drive reliability Status. The S.M.A.R.T. Read Threshold Sector 
Command (DI) then used to read this information. Threshold information may be 
modified or written via the S.M.A.R.T. Write Threshold Value Command (D7). 
Threshold values are obtained from the Saved Configuration Page.