Viking Access Systems Access Systems Safety Gate f1 gate ユーザーズマニュアル

ページ / 50
VIKING TECHNICAL SUPPORT 1.800.908.0884
2 6
Obstruction Sensor (Primary Entrapment Protection)
!
 
IMPORTANT: 
The appropriate “ODS” setting is dependant upon the gate installation 
and construction. Set this feature accordingly. Additional Safety equipment should 
be used to reduce possible risk of injury or vehicle damage.
CONTROL BOARD SETUP
“ODS” Obstruction Detection Sensor
The Obstruction Sensor detects 
obstructions in the path of the traveling 
gate. The dial sets the amount of force 
required to activate the operators inherent 
obstruction detection.
Setting the dial to “0” will require the least 
amount of force to activate;
Setting the dial to “100” will require the 
maximum amount of force to activate.
When the Obstruction Sensor detects 
an obstruction it will:
1.  Stop the gate’s movement and reverse 
it momentarily.
2.  Bring the gate to a resting position.
3.  Disable the Hold Open Timer feature 
until the Gate Operator receives a new 
command.
If second obstruction is detected before 
the gate reaches either limit it will:
1.  Stop the gate’s movement.
2.  Disable the Gate Operator.
3.  Sound the UL Alarm
4. A STOP command must be provided 
to disable the alarm and continue 
operation.
!
 
TECHNICAL TIP:
 The Status LED for the 
“ODS” will indicate the following 
when it has been triggered. 
A.  Solid: Obstruction.                  
Detected a sudden or abrupt increase 
in gate resistance.
B.  Flashing: Overload.                 
Detected a more subtle, but sustained 
increase in gate resistance.
UL325 standard requires an audio 
alarm to go off after two consecutive 
entrapment events sensed by the 
Inherent Entrapment Protection of the 
Gate Operator.
The audio alarm will sound for a period 
of 5 minutes or until a Stop command 
or the “Alarm Reset” switch has been 
actuated. (refer to page 12)