Sony MP595 ユーザーズマニュアル

ページ / 88
Rev 1.5  Jul.08
 
61
8: Sending Data to Your Network 
Application
This chapter discusses how to configure the MP modem to 
send GPS and I/O data to a network server. This is a simple 
process, but if there are any firewalls on your network or your 
service provider’s network, the data must be routed through or 
around the firewall. A general discussion of some methods of 
dealing with firewalls is provided.
This chapter also explains how to retrieve the Unique Mobile 
Device ID from the MP modem. This is the number that 
uniquely identifies each MP modem. Any application that uses 
the GPS and I/O data from the MP modem requires this 
number. 
Configure the MP modem to 
route data to a server
Note:  For a full list of AT 
commands and their parameters, 
see the MP 3G Modems AT 
Command Reference manual 
(document #2130810).
The protocol that defines how MP modem data is packaged is 
called MTP (Monitoring and Tracking Protocol). You can 
configure MTP in 3G Watcher by selecting 
Tools > Options > 
MP > Monitor and Tracking
, or by using the AT command 
AT!MPMTCONF
 and the appropriate parameters.
The MP modem provides four independent reporting engines, 
allowing data to be sent to four different destinations. You can 
specify the destination IP address and port number for each 
engine. This allows, for example, GPS data to be sent to one 
host application, and I/O data to be sent to another.
You can also specify the values for the timers that determine 
the frequency with which the data is to be sent.
Report frequency timers
Note:  You must configure alarm 
triggers locally on the MP 
modem using either 3G Watcher 
or an AT command. 
The low rate timer, alert rate timer, and GPS timer control the 
interval between reports from the MP modem.
The low rate timer sets the interval at which reports are sent in 
the absence of any other trigger or timer. It is in minutes with a 
default of five minutes.