Siemens Outboard Motor S120 ユーザーズマニュアル

ページ / 301
 
Technical data and characteristics 
 
14.2 Data sheets and diagrams 
Data sheet 1FW6290-xxB20-xxxx 
Table 14- 43  1FW6290-xxB20-0Lxx, 1FW6290-xxB20-2Pxx 
Technical data 
1FW6290 
Symbol 
Unit 
-xxB20-0Lxx  -xxB20-2Pxx   
Boundary conditions 
 
 
 
 
 
DC link voltages 
U
ZK
 
600 
600 
 
Water cooling inlet temperature 
T
VORL
 
°C 
35 
35 
 
Rated temperature of winding 
T
N
 
°C 
130 
130 
 
Rated data 
 
 
 
 
 
Rated torque 
M
N
 
Nm 
5760 
5670 
 
Rated current 
I
N
 
95 
120 
 
Maximum speed at rated torque 
n
MAX,MN
 
rpm 
68 
91 
 
Rated power dissipation 
P
V,N
 
kW 
11 
11.1 
 
Limit data 
 
 
 
 
 
Maximum torque 
M
MAX
 
Nm 
10900 
10900 
 
Maximum current 
I
MAX
 
210 
270 
 
Electric power of motor at M
MAX
 
P
EL,MAX
 
kW 
91.9 
10.7 
 
Maximum speed at maximum torque 
n
MAX,MMAX
  rpm 
38 
51 
 
No-load speed 
n
MAX,0
 
rpm 
100 
130 
 
Torque at n = 1 [rpm] 
M
0
 
Nm 
6030 
6030 
 
Current at M
0
 and n = 1 [rpm] 
I
0
 
100 
120 
 
Thermal static torque 
M
0
Nm 
4260 
4260 
 
Thermal stall current 
I
0
70 
90 
 
Physical constants 
 
 
 
 
 
Torque constant at 20 °C 
k
T,20
 
Nm/A 
60.7 
47.3 
 
Voltage constant 
k
E
 
V/(1000/min) 
3669 
2859 
 
Motor constant at 20 °C 
k
M,20
 
Nm/(W)
0.5
 
58.1 
58 
 
Thermal time constant 
t
TH
 
180 
180 
 
No. of pole pairs 
42 
42 
 
Cogging torque 
M
COG
 
Nm 
30 
30 
 
Stator mass 
m
S
 
kg 
187.6 
192.8 
 
Rotor mass 
m
L
 
kg 
73 
73 
 
Rotor moment of inertia 
J
L
 
10
-2
 kgm
2
 
546 
546 
 
Phase resistance of winding at 20 °C 
R
STR, 20
 
Ω 
0.261 
0.159 
 
Phase inductance of winding 
L
STR
 
mH 
5.4 
3.2 
 
Data for main motor cooler *) 
 
 
 
 
 
Maximum dissipated thermal power 
Q
H,MAX
 
kW 
8.3 
8.32 
 
Recommended minimum volume flow 
H,MIN
 
l/min 
14.1 
14.1 
 
Temperature increase of the coolant 
ΔT
H
 
8.4 
8.5 
 
Pressure drop 
Δp
H
 
bar 
2.2 
2.2 
 
1FW6 Built-in torque motors 
Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3 
277