Siemens Network Hardware D410 ユーザーズマニュアル

ページ / 150
 
Commissioning (software) 
 
4.10 Testing the configured axis using the axis control panel 
D410 
Commissioning Manual, 08/2008 Edition 
111
 
4.10 
Testing the configured axis using the axis control panel 
Axis control panel 
The axis control panel is used exclusively for testing axes.  
You can use the axis control panel for the following tasks, for example:  
●  Testing all system components before the axis movement is controlled by a program 
●  Testing as to whether you can move the axis using the axis control panel if a fault is 
detected 
●  Moving the axes for tuning purposes (controller tuning) 
●  Executing active homing 
●  Setting and resetting the axis enable signal 
●  Testing a connected axis 
Prerequisites 
Prerequisites for testing: 
●  The project has been downloaded to the target system. 
●  SIMOTION SCOUT is in online mode. 
Axis test 
1.  Open the "AXES" folder in the Project Navigator and click the "Control panel" entry below 
the axis (for example, Axis_1). 
The axis control panel is displayed. 
 
Figure 4-31  Axis control panel 
2.  In order to view the control range and axis diagnostics data, click "Show/hide control" and 
"Show/hide axis diagnostics".