Siemens Network Hardware D410 ユーザーズマニュアル

ページ / 150
Commissioning (software) 
 
4.2 Configuring the system in offline mode 
 
D410 
62
 
Commissioning Manual, 08/2008 Edition 
2.  Creating an axis 
3.  Using the digital I/O 
4.  Optionally, use TMx, DMC20 or other encoders 
5.  Testing the configured drive 
6.  Testing the configured axis 
Observe the corresponding references. 
4.2 
Configuring the system in offline mode 
4.2.1 
Overview 
Prerequisites for offline configuration 
●  All components and their order number must be known for the offline configuration.  
●  You created a project in SIMOTION SCOUT and added a SIMOTION D410 to the project. 
●  You configured the communication between the programming device / PC and 
SIMOTION D410. 
Procedure 
Steps involved in offline configuring: 
●  Calling the Drive Wizard 
●  Configuring the components 
●  Aligning the HW Config  
●  Downloading the project to SIMOTION D410 
 
 
 
Note 
You can configure all available terminal modules such as TM15 in the course of the 
offline configuration, for example.