Commissioning (software) 
 
4.5 Integrating additional encoders (optional) 
 
D410 
84
 
Commissioning Manual, 08/2008 Edition 
4.5.4 
Configuring external encoders in SIMOTION 
Prerequisite 
Encoder using PROFIBUS/PROFINET 
You have used HW Config to configure an encoder on the PROFIBUS or PROFINET. Two 
different possibilities are available for the encoder connection:  
●  Encoder interconnection using a PROFIdrive message frame (encoder with message 
frame type 81) 
●  Encoder interface as a direct value in the I/O area 
Detailed information is contained in the "SIMOTION TO Axis, Electric/Hydraulic, External 
Encoder" Function Manual 
Encoder on the drive 
You configured a drive with two encoders, and then an electric axis with the PROFIBUS 
message frame to be used. 
Procedure 
1.  Open the wizard for configuring an external encoder by selecting the "External Encoders" 
> "Insert external encoder" folder in the Project Navigator. 
2.  Assign a name in the "Inserting an external encoder" screen form and, if required, enter 
the author and version. 
3.  Execute the wizard for the encoder configuration and enter the appropriate values in the 
screen forms. 
The external encoder is now configured and uses the second value which is transferred by 
means of the selected PROFIBUS message frame. 
Additional references 
Detailed information for the external encoder is contained in the 
SIMOTION SCOUT TO 
Axis, Electric/Hydraulic, External Encoder
 Function Manual.