Siemens Network Hardware SM2 monitoring system ユーザーズマニュアル

ページ / 500
U3585-J-Z125-8-76
199
SM2 operation
Examples
4.7 SM2 monitoring program: examples
Example 1
This simple example illustrates how SM2 is started and stopped again later on.
The following default options are used:
monitoring cycle: 150 seconds
sampling cycle: 800 milliseconds
Reports A (ACTIVITY), M (MEMORY), C (CHANNEL) and D (DEVICE) are output at the
terminal in automatic output mode. SM2 is interrupted after some time with the BREAK
function (terminal key) and terminated.
/START-SM2
START
.           (Output of the reports)
.
.
BREAK or
[K2]
/INFORM-PROGRAM
END
Example 2
In this example, SM2 is started with data output to the SM2 output file. The file is given the
default name SM2.hostname.yyyy.mm.dd.sss.nn. The monitoring cycle is preset to 150
seconds and the sampling cycle to 800 milliseconds. The RESPONSETIME monitoring
program is started (in accordance with definition 1), and monitors up to 1024 connections.
The default options are used for the number of ranges and for the range limits for the
response, think, transaction and wait times.
The SM2 user task is then terminated and monitoring continues in the background.
SM2 is called again after some time to terminate the RESPONSETIME monitoring program
and close the SM2 output file.