4. 
Example Task Tank Content 
 
4.1 
Description of task 
 
Our first program is one to program the calculate the content of tank. 
 
The tank has the shape of an upright cylinder. The fill level of the content is measured by an analog 
sensor. In the task, the value of the fill level should already existed standardized in the meter unit. 
 
A function FC 140 'calculate_tank content' is to be programmed in the program. The diameter and the fill 
level in meter unit are the passed parameters. Result is the tank content in the liter unit. 
 
4.2 
Assignment list / tag table 
 
Because modern programming uses tags and not absolute addresses, the global PLC tags must be 
defined here.  
 
These global PLC tags are descriptive names with a comment for each input and output used in the 
program. The global PLC tags can then be accessed later during programming via their names.  
These global tags can be used in all blocks anywhere in the program. 
 
 
 
Default tag table 
 
Name 
Data type 
Address 
Comment 
FillLevel_tank1 
REAL 
%MD40 
in meters 
Diameter_tank1 
REAL 
%MD44 
in meters 
Content_tank1 
REAL 
%MD48 
in liters