Siemens AT Command Set Cellular Engines Wireless Modules MC35 ユーザーズマニュアル

ページ / 238
AT Command Set
MC35_ATC_01_V04.00
Page 119 of 238
02.04.2002
4.45  AT+CSNS  Single Numbering Scheme
The AT+CSNS command enables the ME to accept incoming calls when no bearer capability infor-
mation is provided with the call, e.g. single numbering scheme calls or calls originitating from analog
devices.
The command must be set before the call comes. By default, when you do not modify the settings,
all calls received without bearer element are assumed to be voice.
Please note that you can use the command if PIN authentication has been done during current ses-
sion. The setting will be automatically saved when you power down the GSM engine with AT^SMSO.
Test command
AT+CSNS=?
Response
+CSNS: (list of supported <mode>s)
OK
Read command
AT+CSNS?
Response
+CSNS: <mode>
OK
Write command
AT+CSNS=[<mode>]
Response
Write command
OK
Parameters
<mode>:
0
Voice
Each call received without bearer element is as-
sumed to be speech.
2
Fax 
Each call received without bearer element is as-
sumed to be an incoming fax.
4
Data
Each call received without bearer element is as-
sumed to be a data call.
Please take into account that the bearer service
parameters set with AT+CBST apply to all data
calls including those received without bearer ca-
pability. To avoid conflicts see Chapter 4.5.
Reference
GSM 07.07
Note