2  Standard V.25ter AT Commands
These AT Commands are related to ITU-T (International Telecommunication Union, Telecommunica-
tion sector) V.25ter document.
MC35 supports the registers S0-S29. You can change S0,S3,S4,S5,S6,S7,S8,S10,S18 by using the
appropriate ATSn commands. All the other registers are read-only and for internal usage only!
2.1  A/  Repeat previous command line
Execute command
A/
Response
Repeats previous command line. Line does not need to end with terminating
character.
Parameter
Reference
V.25ter
Note
•  After beginning with the character “a“ or „A“, a second character “t“ ,”T“ or “/“
has to follow. In case of using a wrong second character, it is necessary to
start again with character “a“ or “A“.
•  If autobauding is active (see +IPR, pg. 38) A/ (and a/) cannot be used.
2.2  +++  Switch from data mode or PPP online mode to command mode
Execute command
+++
Response
This command is only available during a CSD call or a GPRS connection. The
+++
character sequence causes the TA to cancel the data flow over the AT in-
terface and switch to command mode. This allows you to enter AT commands
while maintaining the data connection to the remote device or, accordingly, the
GPRS connection.
OK
To prevent the +++ escape sequence from being misinterpreted as data, it must
be preceded and followed by a pause of at least 1000 ms. The +++ characters
must be entered in quick succession, all within 1000 ms.
Reference
V.25ter
Note:
•  To return from command mode to data or PPP online mode: Enter ATO as de-
scribed in Chapter 2.17.