8.34  AT^SPLW  Write an entry to the preferred operators list
Test command
AT^SPLW=?
Response
TA returns the whole index range supported by the SIM.
^SPLW
: (list of supported <index>s) OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameter
See write command
Write command
AT^SPLW=
<index>
[,<oper>]
Parameter
TA writes an entry to the SIM list of preferred operators at location number <in-
dex>
. If <index> is given but <oper> is left out, the entry is deleted. If <oper> is
given but <index> is left out, <oper> is inserted in the next free location.
<index> location number
<oper>
string type; operator in numeric form; GSM location area identification
number
Note: <oper> is a 5 digit number, 3 digits country code and 2 digits for
the Network provider.
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>