Message
Meaning
How to activate
URC
^SCTM_A: <m>
^SCTM_B: <m>
Battery (A) or board (B) is close to or be-
yond critical temperature limit. URC is is-
sued repeatedly. If <m>=2 or <m>-2, ME
switches off.
AT^SCTM=1
^SBC: Undervoltage
Undervoltage of battery detected. ME will
be switched off within a minute.
AT^SBC=<current>
^SYSSTART
Indicates that ME has successfully been
started.
Note that this URC will not appear if
autobauding is enabled.
Not defined by user
^SYSSTART CHARGE-ONLY
MODE
Only applicable to battery operated MEs:
URC indicates that ME has entered the
Charge-only mode.
Charge-only mode allows charging while
ME is detached from network. Limited
number of AT commands is accessible.
Mode can be launched by connecting the
battery charger to the POWER pins of
the ZIF connector, before or after pow-
ering down ME with AT^SMSO.
Note that this URC will not appear if
autobauding is enabled.
Not defined by user
^SYSSTART ALARM MODE
or, if individual text available:
^SYSSTART ALARM MODE
+CALA: <text>
Indicates that ME has entered Alarm
mode.
RTC alert set with the AT+CALA com-
mand. Executed when ME has been
powered down. Causes ME to wake up
from Power Down mode. Preventing ME
from unintentionally registering to the
network, Alarm mode allows limited op-
eration. Limited number of AT com-
mands is accessible. Do not confuse
with wake-up or reminder call.
Note that this URC will not appear if
autobauding is enabled.
Enabled when you
configure Alarm
mode
+CALA: <text>
Wake-up or reminder call set with
AT+CALA command. Executed while ME
is in normal operation. Do not confuse
with Alarm mode.
Enabled when you
set wake-up call
+CIEV: <text>
Reports changes from indicators listed in
the AT+CIND command specification.
AT+CMER=2,0,0,2
AT+CMER=3,0,0,2