Siemens AT Command Set Cellular Engines Wireless Modules MC35 ユーザーズマニュアル

ページ / 238
AT Command Set
MC35_ATC_01_V04.00
Page 27 of 238
02.04.2002
2.21  ATS3  Write command line termination character
Read command
ATS3?
Response
<n> OK
Write command
ATS3=<n>
This parameter setting determines the character recognized by TA to terminate
an incoming command line.
Response
OK
Parameter
<n>
000-013-127
command line termination character
Reference
V.25ter
Note
2.22  ATS4  Set response formatting character
Read command
ATS4?
Response
<n> OK
Write command
ATS4=<n>
This parameter setting determines the character generated by the TA for result
code and information text.
Response
OK
Parameter
<n>
000-010-127
response formatting character.
Reference
V.25ter
Note
2.23  ATS5  Write command line editing character
Read command
ATS5?
Response
<n> OK
Write command
ATS5=<n>
This parameter setting determines the character recognized by TA as a request
to delete the immediately preceding character from the command line.
Response
OK
Parameter
<n>
000-008-127
command line editing character
Reference
V.25ter
Note