Siemens AT Command Set Cellular Engines Wireless Modules MC35 ユーザーズマニュアル

ページ / 238
AT Command Set
MC35_ATC_01_V04.00
Page 38 of 238
02.04.2002
2.44  AT+ILRR Set TE-TA local rate reporting
Test command
AT+ILRR=?
Response
+ILRR:
 (list of supported <value>s) OK
Parameter
See write command
Read command
AT+ILRR?
Response
+ILRR: <value> OK
Parameter
See write command
Write command
AT+ILRR=
<value>
The write command specifies whether or not an intermediate result code shall in-
dicate the currently used local rate when an incoming or outgoing data call is es-
tablished. The message is transmitted from the DCE (= TA) to the DTE (=TE) be-
fore the final result code of the connection setup (e.g. CONNECT) appears.
Response
OK
Parameter
<value> 0 Disables reporting of local port rate
1 Enables reporting of local port rate
Intermediate result code
+ILLR:<rate>
Parameter
<rate> 
port rate setting in bit per second
           0  (Autobauding, see Chapter 2.45.1)
       300
      600
    1200
    2400
    4800
    9600
 19200
 38400
 57600
115200
Reference
V.25ter
Note
Example
ATD030112233445
+ILRR: 57600
CONNECT 9600/RLP