Siemens AT Command Set Cellular Engines Wireless Modules MC35 ユーザーズマニュアル

ページ / 238
AT Command Set
MC35_ATC_01_V04.00
Page 42 of 238
02.04.2002
3.2  AT+FBADMUL  Error Threshold Multiplier
Read command
AT+FBADMUL?
This command defines the “Copy-Quality-OK” multiplier. The number of lines
received with a bad pixel count is multiplied by this number. If the result ex-
ceeds the total number of lines on the page the error rate is considered too
high. A threshold multiplier value of 20 corresponds to a 5% error rate. A value
of 0 implies that error checking is not present or disabled.
Response
<badmul> 
 OK
Parameter
See write command
Write command
AT+FBADMUL=
<n>
Response
OK
If error is related to ME functionality:
ERROR
Parameter
<n>
0 – 20 – 255
Reference
EIA PN-2388
Note
Used for Faxclass 2 only
3.3  AT+FBOR  Query data bit order
Test command
AT+FBOR=?
Query the bit order for receive-mode. The mode is set by the ME dependent on
the selected Service Class, see “AT+FCLASS  Fax: Select, read or test service
class”,
 pg. 43.
Response
(list of supported bit order modes <bor>s)
OK
Parameter
See write command
Read command
AT+FBOR?
Response
<bor> OK
Parameter
See write command
Write command
AT+FBOR=<bor>
Response
OK
Parameter
<bor>
0
direct bit order for both Phase C and for Phase B/D data.
1
Reversed bit order for Phase C data, direct Bit Order for
Phase B/D data.
Reference
EIA PN-2388
Note