Siemens AT Command Set Cellular Engines Wireless Modules MC35 ユーザーズマニュアル

ページ / 238
AT Command Set
MC35_ATC_01_V04.00
Page 47 of 238
02.04.2002
3.10  AT+FDIS  Query or set session parameters
Test command
AT+FDIS =?
This command allows the controlling application to sense and constrain the
capabilities used for the current session. It uses +FDIS to generate DIS or
DTC messages directly, and uses +FDIS and received DIS messages to gen-
erate DCS messages.
Response
(list of <VR>s), (list of <BR>s), (list of <WD>s), (list of <LN>s), (list of <DF>s),
(list of <EC>s), (list of <BF>s), (list of <ST>s)
Parameter
See write command
Read command
AT+FDIS?
Response
<cdec> OK
Parameter
See write command
Write command
AT+FDIS =
<VR>,<BR>,<WD>,
<LN>,<DF>,<EC>,
<BF>,<ST>
Response
OK
Parameter
Vertical Resolution
VR
0
normal, 98 lpi
1
fine, 196 lpi
Bit Rate
BR
0
2400 bit/s, V.27ter
1
4800 bit/s, V.27ter
2
7200 bit/s, V.29
3
9600 bit/s, V.29
Page Width
WD
0 *)
1728 pixels in 215mm
1
2048 pixels in 255 mm
2
2432 pixels in 303 mm
3
1216 pixels in 151 mm
4
864 pixels in 107 mm
Page Length
LN
0
A4, 297mm
1
B4, 364mm
2
unlimited length
Data Compression Format DF
0 *)
1-D modified Huffman
1
2-D modified read
2
2-D uncompressed mode
Error correction
EC
0 *)
disable ECM
(Annex A/T.30)
1
enable ECM, 64 bytes/frame
2
enable ECM, 256 bytes/frame
Binary File mode
BF
0 *)
disable BFT
Transfer Mode
1
enable BFT
Scan Time/Line
ST
0 *)
0 ms
(at VR= normal)
1
5  ms
2
10 ms
3
10 ms
4
20 ms
5
20 ms
6
40 ms
7
40 ms
*) Note: Only the default value needs to be implemented. Use test command
to check which parameter values are really possible!
Reference
EIA PN-2388
Note
Used for Faxclass 2 only