RuggedCom RUGGEDBACKBONE RX5000 ユーザーズマニュアル

ページ / 35
4. Technical Specifications
RuggedCom® RuggedBackbone™
29
RX5000 Installation Guide Rev106
4. Technical Specifications
4.1. Power Supply Specifications
Input Range
Power Supply Type
Min
Max
Internal Fuse Rating
Max. Power
Consumption
a
HI (125/250 VDC)
b
88 VDC
300 VDC
6.3A, 250V(T)
c
84 W
d
HI (110/230 VAC)
b
85 VAC
264 VAC
6.3A, 250V(T)
c
84 W
d
a
 Power consumption varies based on configuration, i.e. the number and type of ports. Each 10/100Base-TX port consumes
roughly 1W less than a fiber optic port.
b
 The “HI” power supply is the same power supply for both AC and DC.
c
 (T) denotes time-delay fuse. Internal fuse is not user-replaceable.
d
 Rating at 85°C ambient temperature at worst-case load.
Table 4.1. Power Supply Specifications
4.2. Critical Alarm Relay Specifications
Parameter
Value (Resistive Load)
Max Switching Voltage
250 VAC, 125 VDC
Rated Switching Current
2A@250VAC, 2A@30VDC
Table 4.2. Critical Alarm Relay Specifications
4.3. Copper Ethernet Port Specifications
The RX5000 can be ordered with several different modules which contain 10/100Tx or 10/100/1000Tx
Ethernet ports. All copper Ethernet ports have the following specifications:
Parameter
Specification
Notes
Speed
10/100 or 10/100/1000 Mbps
Auto-negotiating
Duplex
FDX / HDX
Auto-negotiating
Cable-Type
> Category 5
Shielded/Unshielded
Wiring Standard
TIA/EIA T568A/B
Auto-Crossover, Auto-Polarity
Max Distance
100 m
 
Connector
RJ45
 
Isolation
1.5kV
RMS 1-minute
Table 4.3. Copper Ethernet Port Specifications