RuggedCom RUGGEDBACKBONE RX5000 ユーザーズマニュアル
2. RuggedBackbone™ Modules
RuggedCom® RuggedBackbone™
9
RX5000 Installation Guide Rev106
2. RuggedBackbone™ Modules
The RX5000 chassis comprises ten slots, each one of which is designed to accommodate a particular
module.
module.
“L1”, etc.) denotes the type of module that may be installed at that position in the chassis.
Figure 2.1. Chassis Slot Assignment
The slot name markings in the diagram above represent the following RuggedBackbone™ modules:
CM
The Control Module is the central processing unit of the system. Refer to
SM
The Switch Module contains the chassis-wide Ethernet switch fabric that interconnects Ethernet
ports on all installed line modules. Refer to
ports on all installed line modules. Refer to
L1..L6
for detail.
PM1, PM2
Dual, redundant, power supply modules may be installed - refer to
for detail.
All supported modules are built to the RuggedRated™ specifications of the RuggedBackbone™
RX5000. Each of the module types is detailed in the following sections.
RX5000. Each of the module types is detailed in the following sections.
2.1. Installing A Module In The Chassis
In order to install a module into the RuggedBackbone™ chassis, align the module guide ribs with the
channels on the chassis, and push the module in as far as it will go. There is a detent position that must
be pushed through to properly seat the connectors - this is the added resistance from the grounding
springs. When properly seated, the module flange will rest on the main chassis frame. Tighten the
thumbscrews using finger strength only.
channels on the chassis, and push the module in as far as it will go. There is a detent position that must
be pushed through to properly seat the connectors - this is the added resistance from the grounding
springs. When properly seated, the module flange will rest on the main chassis frame. Tighten the
thumbscrews using finger strength only.