RuggedCom RUGGEDBACKBONE RX5000 ユーザーズマニュアル

ページ / 35
2. RuggedBackbone™ Modules
RuggedCom® RuggedBackbone™
9
RX5000 Installation Guide Rev106
2. RuggedBackbone™ Modules
The RX5000 chassis comprises ten slots, each one of which is designed to accommodate a particular
module. 
 shows the rear panel view of the RX5000. The slot name at each position (“PM1”,
“L1”, etc.) denotes the type of module that may be installed at that position in the chassis.
Figure 2.1. Chassis Slot Assignment
The slot name markings in the diagram above represent the following RuggedBackbone™ modules:
CM
The  Control  Module  is  the  central  processing  unit  of  the  system.  Refer  to 
SM
The Switch Module contains the chassis-wide Ethernet switch fabric that interconnects Ethernet
ports on all installed line modules. Refer to 
L1..L6
 for detail.
PM1, PM2
Dual, redundant, power supply modules may be installed - refer to 
for detail.
All  supported  modules  are  built  to  the  RuggedRated™  specifications  of  the  RuggedBackbone™
RX5000. Each of the module types is detailed in the following sections.
2.1. Installing A Module In The Chassis
In order to install a module into the RuggedBackbone™ chassis, align the module guide ribs with the
channels on the chassis, and push the module in as far as it will go. There is a detent position that must
be pushed through to properly seat the connectors - this is the added resistance from the grounding
springs. When properly seated, the module flange will rest on the main chassis frame. Tighten the
thumbscrews using finger strength only.