Renesas R61509V ユーザーズマニュアル

ページ / 181
R61509V 
        Target 
Spec 
 
Rev. 0.11 April 25, 2008, page 95 of 181  
 
Basic Mode Operation of the R61509V 
The basic operation modes of the R61509V are shown in the following diagram.  When making a transition 
from one mode to another, refer to instruction setting sequence. 
Reset
state
Display
OFF
Internal clock
display 
operation
VSYNC
interface
RGB
interface (1)
RGB
interface (2)
Initial setting
Display ON sequence
(Power ON sequence)
VSYNC i/F sequence 2
(DM=10, RM=0)
RGB i/F (2) sequence 1
(DM=01, RM=0)
moving picture
display
RAM access via
system i/F while displaying
moving picture
moving picture
display
262k-color
mode
8-color
mode
Partial 
display
Display color control
262k         8
color display
sequence
8          262k
color display
sequence 
Exit shut down mode
Shut down
mode
DSTB = 1
Deep
standby set
RGB i/F (2) sequence 2
(DM=01, RM=1)
VSYNC i/F sequence 1
(DM=00, RM=0)
RGB i/F (1) sequence 1
(DM=01, RM=1)
RGB i/F (1) sequence 2
(DM=00, RM=0)
Partial 
display
sequence 2
Partial 
display
sequence 1
Display OFF sequence
(Power OFF sequence)
Reset
 
Figure 12