Psion Teklogix 8100107B ユーザーズマニュアル

ページ / 396
Chapter 6: Settings
Decoded (Intermec ISCP)
184
WORKABOUT PRO Hand-Held Computer With Windows Mobile 5.0 User Manual
transmitted. Choosing Concatenated or Single transmits single codes or 
concatenated codes. If only one code of a pair is read, that code will be transmitted 
as a single code. If both codes in a pair are detected, they will be concatenated 
provided that ISBT Concat Any Pair (see below) is enabled.
ISBT Concat Any Pair
Enabling this parameter causes all code pairs that can be, to be concatenated even if 
they do not comply with Section 4.1 of the “ISBT 128 Bar Code Symbology and 
Application Specification for Labeling of Whole Blood and Blood Components” 
(June 2000, Version 1.2.1).
Reading Range
Determines the reading distance from which a bar code can be successfully scanned. 
The default setting Extended, allows for increased reading distance. 
Check Digit Verification
The available options for this parameter are Disabled or French CIP. This parameter 
uses the specified algorithm of the option you've chosen to ensure the integrity of 
the symbol data before transmitting. If the data does not contain that algorithm, the 
data is not transmitted. 
Note: French CIP (French pharmaceutical) is only used with bar codes contain-
ing 7 characters.
Minimum Length
Minimum lengths for the bar code can be set from 0 to 255. The length of a code 
refers to the number of characters (i.e., human readable characters), including 
check digit(s). 
Field Size/Char
Refer to page 148 for details.
6.25.3.5
EAN 13 Settings
Enabled
Set this parameter to on to enable “EAN 13”.