Psion Teklogix 8100107B ユーザーズマニュアル

ページ / 396
WORKABOUT PRO Hand-Held Computer With Windows Mobile 5.0 User Manual 191
Chapter 6: Settings
Decoded (Intermec ISCP)
Reading Range
This parameter determines the reading distance from which a bar code can be 
successfully scanned. The default setting, Extended, allows for increased 
reading distance. 
Check Digit Verification
The available options for this parameter are DisabledMOD 10 Check and French 
CIP
. “Check Digit Verification” uses the specified algorithm of the option you've 
chosen to ensure the integrity of the symbol data before transmitting. If the data does 
not contain that algorithm, the data is not transmitted. 
Note: French CIP (French pharmaceutical) is only used with bar codes contain-
ing 7 characters.
Transmit Check Digit
If the check digit is to be transmitted with the data, this parameter must be enabled.
Set Length L1, Set Length L2, And Set Length L3
Lengths for “Interleaved 2 of 5” can be set from 0 to 255. The length of a code 
refers to the number of characters (i.e., human readable characters), including 
check digit(s). 
Double-tapping on these parameters displays dialog boxes where you can define the 
code length that will be recognized by your scanner.
Length Mode
You can chose to set L1 as Minimum Length or L1,L2,L3 as Fixed Length.
Field Size/Char
Refer to page 148 for details.
6.25.3.15 Matrix 2 of 5
Enabled
Set this parameter to on to enable “Matrix 2 of 5”.