CDM-600 Satellite Modem 
Revision 7 
ODU Operation 
MN/CDM600.IOM 
D–11 
D.2.20 (ODU,ENABLE,1:1,CSAT#1, 
ALARMS)  
       STORED-ALARMS 
 (ODU,ENABLE,1:1,CSAT#2, 
ALARMS)  
       STORED-ALARMS 
 (ODU,ENABLE,STANDALONE 
CSAT, ALARMS)  STORED-ALARMS 
As the stored events are being read, the screen will show: 
 
 READING STORED FAULTS.....  PLEASE WAIT 
  
 
Then, the Stored Alarms screen will be shown. An example is shown below: 
 
 STORED ALARMS:  CLEAR-ALL: NO  (NO,YES) 
 IF #84: 10/14/04  12:52:08  POWER ON
 
 
Use the [
←] or [→] keys to select between the log entries and the CLEAR-ALL option. 
 
With the cursor on the entry number, use the [
↑] or [↓] keys to view through the entries. 
Up to 99 entries are stored. Each entry shows: 
the entry type: IF = information, FT = fault, OK = fault cleared 
the entry number – 00 though 99 
the date (international format) 
the time 
a description of the fault/information 
 
To clear the Stored Alarms Log, select YES in the CLEAR-ALL option and press 
ENTER. 
D.2.21 
(ODU,ENABLE,1:1,CSAT#1) 
   INFORMATION 
 
(ODU,ENABLE,1:1,CSAT#2) 
   INFORMATION 
 (ODU,ENABLE,STANDALONE 
CSAT) 
  INFORMATION 
 INFO:   MODEL   TX   RX   MISC   LNA 
  
 
Use the [
←] or [→] keys to select the type of information to view, then press ENTER.