Premier Mounts Modem CDM-600 ユーザーズマニュアル
CDM-600 Satellite Modem
Revision 7
ODU Operation
MN/CDM600.IOM
D–11
D.2.20 (ODU,ENABLE,1:1,CSAT#1,
ALARMS)
STORED-ALARMS
(ODU,ENABLE,1:1,CSAT#2,
ALARMS)
STORED-ALARMS
(ODU,ENABLE,STANDALONE
CSAT, ALARMS) STORED-ALARMS
As the stored events are being read, the screen will show:
READING STORED FAULTS..... PLEASE WAIT
READING STORED FAULTS..... PLEASE WAIT
Then, the Stored Alarms screen will be shown. An example is shown below:
STORED ALARMS: CLEAR-ALL: NO (NO,YES)
IF #84: 10/14/04 12:52:08 POWER ON
Use the [
←] or [→] keys to select between the log entries and the CLEAR-ALL option.
With the cursor on the entry number, use the [
↑] or [↓] keys to view through the entries.
Up to 99 entries are stored. Each entry shows:
the entry type: IF = information, FT = fault, OK = fault cleared
the entry number – 00 though 99
the date (international format)
the time
a description of the fault/information
the entry number – 00 though 99
the date (international format)
the time
a description of the fault/information
To clear the Stored Alarms Log, select YES in the CLEAR-ALL option and press
ENTER.
D.2.21
(ODU,ENABLE,1:1,CSAT#1)
INFORMATION
(ODU,ENABLE,1:1,CSAT#2)
INFORMATION
(ODU,ENABLE,STANDALONE
CSAT)
INFORMATION
INFO: MODEL TX RX MISC LNA
Use the [
←] or [→] keys to select the type of information to view, then press ENTER.