Table  3-1: Troubleshooting Steps 
Symptom 
Corrective Steps 
Is it safe to keep 
the Midspan 
running while a port 
indicator is orange? 
 
This is a safe condition. The orange indication is due to: 
1.  A device, not compliant to IEEE 802.3af, was detected.  
2.  Terminals 4/5 and 7/8 are shorted together.  
3.  Forced external power fed into the port.  
During these conditions, port power is disconnected. 
 
Technical Specifications 
Physical Specifications 
Dimensions 
44 x 433 x 302 mm  
   (h x w x l)  
(1.75 x 17 x 11.9 inch) 
Weight 
4 kg (8.8 lb) 
 
Environmental Specifications 
Temperature 
  - Operating    
 
 
 
0 to 40 °C (32 to 104 °F)  
  - Storage  
 
 
 
 
-20 to 70 °C (-4 to 158 °F) 
Humidity    
 
 
 
 
10 to 90% (non-condensing) 
 
Electrical Specifications 
Parameter 
PD-6006 
PD-6012 
PD-6024 
AC Input Voltage 
90 to 264 VAC at 47-63 Hz 
DC Input Voltage 
46 to 57 VDC
Input Current @ 115 VAC  
4 A max.
Input at 48 VDC 
10 A max.
Total Output Power (1) 
92 W max. 
200 W max. 
200 W max. 
Output Power, per Port 
15.4 W  (not to exceed Total Output Power)
Nominal Output Voltage  
44 to 57 VDC 
Total Output Power (2) 
400 W 
(1)  Using AC Power 