accomplished by enabling each radio to analyze the signal quality of its current control channel and 
compare it with the signal quality of the control channel for each site in its adjacency scan list. (The signal 
quality metric used for the ProScan algorithm is based on a combination of both Received Signal Strength 
Indicator [RSSI] and Control Channel Verification [CCV] measurements.)  When the selected system’s 
signal quality level degrades below a pre-programmed level, the radio will begin to look for a better 
control channel. Once a control channel that exceeds the pre-programmed parameters is found, the radio 
will change to the new system and emit a tone. If the control channel is completely lost the radio, will 
enter Wide Area System Scanning and search the programmed adjacent systems until a suitable control 
channel is found. 
9.9.3  Priority System Scan 
The radio can also be programmed for Priority System Scan. (To ensure that this feature operates 
correctly, the control channel of the priority system must be located on channel one unless you are using 
the ProScan algorithm.)  The priority system is the desired or preferred system. While receiving the 
control channel of the selected system, the radio will periodically leave the selected system and search for 
the control channel of the priority system at a programmable rate. The programmable rate is defined by 
the value in the Priority Scan Time control, (unless the ProSound/ProScan algorithm is enabled as 
explained below). This priority scan timer is reset each time the PTT button is pressed or when a call is 
received. If the priority system control channel is found, or meets the predefined ProScan criteria, the 
radio will automatically switch to the priority system. 
9.9.4  When Wide Area System Scan Is Enabled 
If the radio cannot find the control channel of the selected system and begins Wide Area System Scan 
(WA Scan), the radio will only scan for the priority system control channel if the priority system is in the 
WA Scan list. 
9.9.5  When ProScan Is Enabled 
The radio monitors the priority system and will switch to the priority system if the priority system meets 
the criteria defined in the “ProSound/ProScan Options” dialog box. If ProScan is enabled, the rate at 
which the radio will scan for the priority system is defined by the System Sample Time control. 
9.9.6  Menu Selection 
Press MENU and then use the 
 ramp control to scroll through the selections until SYS SCAN is 
displayed. Then press MENU to toggle the System Scan state. The SYSC ON or SYSC OFF display 
message is displayed for two seconds to show the new state. 
9.9.7  Pre-Programmed Keypad Key 
Press the pre-programmed key and the SYSC ON or SYSC OFF display message is displayed for two 
seconds to show the new state. 
9.10  GROUP SCAN OPERATION 
Only Groups that are part of the radio's scan list will be scanned. Groups are added to the scan list on a 
per system basis through programming, the radio keypad, or both, dependent upon programming. This 
scan list can be changed by the user from the keypad unless programmed otherwise. Each system's group 
scan list is retained in memory when the radio is turned off. The M7200 Series mobile radio can also be