Pelco TLR3168 Time-Lapse VCR C673M (2/01) ユーザーズマニュアル

ページ / 76
Pelco Manual C673M (2/01)
13
CONNECTING THE VCR TO A MULTIPLEXER
NOTE: 
 Cameras and
monitors are connected to
the multiplexer. Figure 2
shows the connection be-
tween the VCR and an
MX4000 Series Genex Mul-
tiplexer. Refer to the multi-
plexer manual for additional
component connections.
Figure 2.  Connecting a VCR to a Multiplexer
Figure 2 shows how to connect the VCR to an MX4000 Series Genex
®
 Multiplexer.
For Automatic Speed Tracking (“B” lines in Figure 2)
This lets the VCR control the multiplexer’s recording speed. It is the most efficient
recording method.
1.
Connect the CLK output to the multiplexer’s head switching (HS) input to
synchronize camera switching.
2.
Connect the multiplexer’s ground terminal to the VCR’s GND terminal.
For Alarm Recording (“A” lines in Figure 2)
This is to start and stop recording when there are alarms.
1.
Connect the multiplexer’s normally open (N.O.) relay terminal to the VCR’s ALM
IN (alarm input) terminal.
2.
Connect the common (C) terminal to the VCR’s GND terminal.
00430
REMOTE
RESET
IN
OUT
AUDIO
IN
OUT
VIDEO
ALM RST
GND
REC
MODE
CLK CALL
IN
OUT
BATTERY
OPEN
110-240V 50/60 Hz
VCR
AUX
MAIN
SPOT
SVHS
 
OUT                
 
SVHS
 
IN     COM    
N
N
 
H
C
O
C
ALARMS
1 2 3 4 5    
6
8
 
9 10
14 15 16
12 13
COAXIAL
CABLE
COAXIAL
CABLE
A
B
MX4000 GENEX  SERIES MULTIPLEXER
MIC