Pelco TLR3168 Time-Lapse VCR C673M (2/01) ユーザーズマニュアル

ページ / 76
62
Pelco Manual C673M (2/01)
COMMANDS AND RESPONSES CHART
The chart uses the following conventions:
*
An asterisk indicates a character or digit (for example, *** indicates three characters or
digits).
#1
This means input the code according to the DELIMITER<RECEIVE> setting (CR
[0DH] or CR [0DH] + LF [0AH]).
#2
This means the code according to the DELIMITER<SEND> setting (CR [0DH] or CR
[0DH] + LF [0AH]) will be input).
No.
Commands
Functions
Status After Normal
Explanation of Status
Execution
1
PW#1
Power ON/OFF
RC#2EX#2
Command received and
carried out
2
PW0#1
Power OFF
Same as above
Same as above
3
PW1#1
Power ON
Same as above
Same as above
4
EJ#1
Eject
Same as above
Same as above
5
SP#1
Stop
Same as above
Same as above
6
PB#1
Playback
Same as above
Same as above
7
RP#1
Reverse playback
Same as above
Same as above
8
FF#1
Fast forward
Same as above
Same as above
9
RW#1
Rewind
Same as above
Same as above
10
RC#1
Recording
Same as above
Same as above
11
CM#1
Counter memory stop
Same as above
Same as above
12
PU#1
Pause ON/OFF
Same as above
Same as above
13
PU0#1
Pause OFF
Same as above
Same as above
14
PU1#1
Pause ON
Same as above
Same as above
15
FA#1
Frame advance (when still)
Same as above
Same as above
16
RA#1
Reverse frame advance (when still)
Same as above
Same as above
17
LK#1
Lock OFF
Same as above
Same as above
18
LK0#1
Lock ON
Same as above
Same as above
19
LK1#1
Lock All ON
Same as above
Same as above
20
SF#1
Skip search (forward)
Same as above
Same as above
21
SR#1
Skip search (reverse)
Same as above
Same as above
22
IF***#1
Index search (forward) up to
Same as above
Same as above
(***=001-255)
23
IR***#1
Index search (reverse) up to
Same as above
Same as above
(***=001-255)
24
IN#1
Inquiry about current index no.
RC#2D***#2
Index no. is ***=001-255
(during index search)
25
TR#1
Timer recording ON/OFF
RC#2EX#2
Command received and
carried out
26
TR0#1
Timer recording OFF
Same as above
Same as above
27
TR1#1
Timer recording ON
Same as above
Same as above
28
TP#1
Inquiry about current executing
RC#2TN*#2
Timer program no. is *=1-8
timer program no.
(NOTE: ER08 when not timer
recording.)
(Continued on next page)