Appendix A  Programming the Watchdog Timer
A.1  Programming the Watchdog Timer
To program the watchdog timer, you must write a program which writes I/
O port address 440 (hex). The output data is a time interval value. The 
value range is from 01 (hex) to 3F (hex), and the related time interval is 
from 1 sec. to 63 sec.
Data Time Interval
01
1 sec.
02
2 sec.
03
3 sec.
04
4 sec.
ï
ï
ï
ï
ï
ï
3F
63 sec.
After data entry, your program must refresh the watchdog timer by rewrit-
ing the I/O port 440 (hex) while simultaneously setting it. When you want 
to disable the watchdog timer, your program should read I/O port 440 
(hex).
The following example shows how you might program the watchdog 
timer:
 
;-----------------------------------------------------------------------------------
; Enter the extended function mode, interruptible double-write |
;-----------------------------------------------------------------------------------
MOV DX,2EH
MOV AL,87H
OUT DX,AL
OUT DX,AL