Toshiba VF-AS1 ユーザーズマニュアル

ページ / 326
  E6581301 
F-1 
6. Extended parameters 
 
Extended parameters are provided for sophisticated operation, fine adjustment and other special purposes.   
Ÿ
 Refer to Section 11, Table of parameters. 
6.1 
Input/output parameters 
6.1.1  Low-speed  signal!!!!
H
H
H
H    : Low-speed signal output frequency 
[Parameter setting] 
Title 
Function 
Adjustment range 
Default setting 
H
Low-speed signal output frequency 
~WN Hz 

Output frequency [Hz]
Time [s] 
H
Low-speed signal output 
P24-OUT1 terminals (Default setting) 
P24-OUT2 terminals   
FLA-FLB-FLC terminals 
ON 
OFF 
Low-speed signal output: Inverted
ON 
OFF 
0
Set frequency
[Connection diagram (SW1 set to sink logic)] 
P24
OUT1 (or OUT2)
NO
CC
Ry
• Function 
When the output frequency exceeds the setting of H an ON signal will be generated. This signal can be 
used as an electromagnetic brake excitation/release signal. 
★Through the open collector terminal OUT1 or OUT2 (24Vdc-50mA [max.]).
• Output terminal setting 
The low-speed signal (ON signal) output function has been assigned to the terminal OUT1 by default. This 
setting must be changed to invert the polarity of the signal.   
[Parameter setting] 
Title 
Function 
Adjustment range 
Example of setting 
H
Output terminal function selection 
1(OUT1) 
~
(ON signal) or   
(OFF signal)
Note: To put out signals to OUT2, select the parameter H.