Toshiba VF-AS1 ユーザーズマニュアル

ページ / 326
!
  E6581301!
M-6 
13
(Continued overleaf) 
(Continued) 
KPKV
Parameters in 
the process of 
initialization 
•Parameters are being initialized to 
default values. 
•Normal if the message disappears after a while 
(several seconds to several tens of seconds). 
CVP In auto-tuning 1
•Auto-tuning 1 in process. 
•Normal if it the message disappears after a few 
seconds. 
NUVR
Auto-stop 
because of 
continuous 
operation at the 
lower-limit 
frequency 
•The automatic stop function of 
H is being performed. 
•This function is deactivated when the command 
frequency becomes 0.2Hz or more higher than the 
lower-limit frequency (LL) or when a command for 
stopping operation is entered. 
UVQR
Momentary 
power failure 
slowdown stop 
prohibition 
function 
activated. 
•The deceleration stop function of 
WXE (regenerative power 
ride-through control) is activated. 
•To restart operation, reset the inverter or input an 
operation signal again. 
JGCF/
GPF
Display of 
first/last data 
items 
•First and last data in the CWJ
group. 
•To exit from the group, press the MODE key. 
VWP
During learning
•Learning for brake sequence 
operation or light-load high-speed 
operation is currently in progress.
•To cancel learning, suspend it and set learning 
parameters H to . 
VWP
Brake sequence 
learning error 
•Braking operation is not performed 
normally. 
•The load is too heavy. 
•There are some operation errors. 
•Brake signal output (, ) is not assigned to 
the control output terminal.   
•The brake function mode selection parameter 
(H) is not set.   
•Learning is performed while the load is lifted 
VWP
Light-load 
high-speed 
learning 
operation error
•There are some errors in the 
operation for learning for light-load 
high-speed operation.   
•Check whether the learning operation for light-load 
high-speed operation is performed correctly.   
Ÿ
 Refer to 6.16.   
VWP
Light-load 
high-speed 
learning 
overload error 
•Learning operation for light-load 
high-speed operation is performed 
while the load is lifted.   
•Motor constants (XN, XNX, 
H to H) are not 
entered correctly.   
•Check the load.   
•Check the motor constant setting.   
WPFZ
Key operation 
permitted 
temporarily 
•This message appears if the 
ENTER key is pressed and held 
down for 5 seconds or more when 
key operation is prohibited by 
H. 
•When this message is displayed, all the keys are 
operational. To prohibit key operation again, turn 
off the inverter and then turn it back on. 
Note: In the case of DC injection breaking ON/OFF function is selected for an input terminal; if “FD” disappears as a 
result of open-circuit between the terminal and CC, it is normal. 
[Pre-alarm display] 
Error 
code
Description 
Possible causes 
Remedies 
E
Overcurrent pre-alarm 
Same as QE (Overcurrent) 
Same as QE (Overcurrent) 
R
Overvoltage pre-alarm 
Achieving PBR operation 
level 
Same as QR (Overvoltage) 
R blink while PBR is operating is not 
an error. 
Same as QR (Overvoltage) 
R blink while PBR is operating is not 
an error. 
N
Overload pre-alarm 
Same as QN and QN (Overload)
Same as QN and QN (Overload)
J
Overheat pre-alarm 
Same as QJ (Overheat) 
Same as QJ (Overheat) 
V
Communication error 
•Various transmission errors occur 
when computer is linked up with 
inverter system. 
•Various transmission errors occur in 
inverter to inverter communication 
(slave side). Time-out or trip in master 
side. 
•For measures to correct various kinds 
of data transmission errors, refer to 
the instruction manual for the!
communications device used 
specified in Section 6.42. 
•Check the master inverter. 
If two or more problems arise simultaneously, one of the following alarms appears and blinks. 
ER, RN, NJ, ERN, ……, ERNJ
The blinking alarms E, R, N, J, Vare displayed in this order from left to right.