Toshiba VF-AS1 ユーザーズマニュアル

ページ / 326
  E6581301 
E-1 
5. Basic parameters 
This parameter is a basic parameter for the operation of the inverter. 
Ÿ
 Refer to Section 11, Table of parameters. 
5.1 
History function 



 CWJ
CWJ
CWJ
CWJ


  : History function 
Note 1:  If no history information is stored, this parameter is skipped and the next parameter CW. 
Note 2:  JGCF and GPF are added respectively to the first and last parameters in a history of changes.   
[Setting methods] 
Key operated 
LED display
Operation 

Displays the operation frequency (operation stopped).   
(When standard monitor display selection H=
[Output frequency]) 
CWJ
The first basic parameter “History function (CWJ)” is 
displayed. 
CEE
The parameter that was set or changed last is displayed. 

Press the ENTER key to display the set value. 

Press the        key and        key to change set value. 

⇔CEE
Press the ENTER key to save the changed value. The 
parameter name and the programmed value will flash on 
and off alternately. 
              (              )
**** 
Use the same steps as those given above to display 
parameters that you want to search for or change setting 
with the        key and        key. 
              (              )
JGCF
(GPF)  
JGCF
: First historic record 
GPF: Last historic record 
Parameter display
CWJ
HTH

Press the MODE key to return to the parameter setting 
mode CWJ.   
After that you can press the MODE key to return to the 
status monitor mode or the standard monitor mode (display 
of operation frequency).   
• Function 
Automatically searches for 5 latest parameters that are programmed with values different from 
the standard default setting and displays them in the CWJ. Parameter setting can also be 
changed within this group CWJ.   
This function comes in very handy when you adjust the inverter repeatedly using the same 
parameter.   
MODE
ENT
ENT
ENT
MODE
MODE
MODE