Optima Company Optima 45 - 3 ユーザーズマニュアル

ページ / 49
Optima 45 - 3
  
 
 
 
 
 
 
 
 
SPECIFICATIONS 
 
Natural Gas (NG) 
Propane (LP) 
Manifold Pressure 
1.6 - 3.5 in. W.C. (0.4 - 0.9 kPa)  6.3 - 10.0 in. W.C. (1.6 - 2.5 kPa) 
Minimum Supply 
Pressure for Purpose of 
Input Adjustment  
4.5 in. w.c. (1.2 kPa) 
11.0 in. w.c. (2.8 kPa) 
Orifice Size 
#37 DMS (2.64 mm dia.) 
#52 DMS (1.60 mm dia.) 
Altitude 
0-4500 ft (0 - 1372 M) 
0 - 4500 ft (0 - 1372 M) 
Primary Air Opening 
3/16” (5 mm) 
3/8” (9 mm) 
Nominal Input Rating 
18,750 - 28,000 BTU/hr 
(5.5 - 8.2 kW) 
19,600 - 28,000 BTU/hr 
(5.7 - 8.2 kW) 
This appliance is tested and safety approved under the following US and Canadian gas 
appliance standards: 
- ANSI Z21.88b-2003 / CSA 2.33b-2003, Vented Gas Fireplace Heaters 
- CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes 
 
Please contact Archgard Industries Ltd., if you have any questions regarding the certification of 
this appliance. 
APPLIANCE CERTIFICATION 
INSTALLATION CODES 
This appliance must be installed by a qualified gas appliance installer.  The installation must 
conform with the local codes or, in the absence of local codes, with the current National Fuel Gas 
Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code, CAN/CGA-B149, in Canada. 
Electrical connections and grounding must conform with local code, or current National Electrical 
code, ANSI/NFPA No. 70-1987, in the US and in Canada, the current Canadian Electrical Code, 
CSA C22.1. 
HIGH ALTITUDE INSTALLATION 
When installing this appliance beyond 4500 ft. (1372 M) above sea level, the appliance must 
be properly de-rated and installed according to local codes, in the absence of local codes, with 
the current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code, 
CAN/CGA-B149, in Canada.